{"created":"2023-06-20T16:37:31.996323+00:00","id":7307,"links":{},"metadata":{"_buckets":{"deposit":"b19f7bd0-bea7-46d2-a250-388ea485870b"},"_deposit":{"created_by":3,"id":"7307","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7307"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00007307","sets":["14:923:1711:1721","21:3039:3241:3285"]},"author_link":["12505","12504","12506","12507"],"item_2_alternative_title_3":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Optimum placement of response control damper using topology optimization method for frame structure"}]},"item_2_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-12-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"44","bibliographicPageEnd":"58","bibliographicPageStart":"53","bibliographic_titles":[{"bibliographic_title":"近畿大学工学部研究報告"},{"bibliographic_title":"Research reports of the Faculty of Engineering, Kinki University","bibliographic_titleLang":"en"}]}]},"item_2_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[Abstract]Recently, response control dampers are often used for improving seismic performance of building. The placement of the dampers is important because the seismic performance of building depends on it. Therefore, in this paper, a method to obtain an optimum placement of response control dampers is proposed. In the present method, the optimum placement of the dampers is obtained by topology optimization method for frame structure (i.e. ground structure method). The response control dampers work for dynamic external force, but, in this method, the placement of the dampers is obtained by the optimization analysis for static external force. The effectiveness of the optimum placements obtained by the present method is verified by the dynamic response analysis of some numerical examples.","subitem_description_type":"Abstract"}]},"item_2_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学工学部"}]},"item_2_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0386491X","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"KUBO, Kazuki"},{"subitem_text_language":"en","subitem_text_value":"FUJII, Daiji"},{"subitem_text_language":"en","subitem_text_value":"OTA, Kazuhiko"},{"subitem_text_language":"en","subitem_text_value":"NONAKA, Tetsuya"}]},"item_2_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大学大学院システム工学専攻"},{"subitem_text_value":"近畿大学工学部建築学科"},{"subitem_text_value":"近畿大学工学部建築学科"},{"subitem_text_value":"(株)地震工学研究開発センター"}]},"item_2_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Graduate School of System Engineering, Kinki University"},{"subitem_text_value":"Department of Architecture, Faculty of Engineering Kinki University"},{"subitem_text_value":"Department of Architecture, Faculty of Engineering Kinki University"},{"subitem_text_value":"Earthquake Engineering Research Center Inc."}]},"item_2_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"久保, 和毅"},{"creatorName":"クボ, カズキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤井, 大地"},{"creatorName":"フジイ, ダイジ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大田, 和彦"},{"creatorName":"オオタ, カズヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"野中, 哲也"},{"creatorName":"ノナカ, テツヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-18"}],"displaytype":"detail","filename":"AN00063799-20101220-0053.pdf","filesize":[{"value":"3.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AN00063799-20101220-0053.pdf","url":"https://kindai.repo.nii.ac.jp/record/7307/files/AN00063799-20101220-0053.pdf"},"version_id":"17662080-0f39-4baf-bf8e-3cc9f1da4ef7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Response control damper","subitem_subject_scheme":"Other"},{"subitem_subject":"Optimum placement","subitem_subject_scheme":"Other"},{"subitem_subject":"Topology optimization","subitem_subject_scheme":"Other"},{"subitem_subject":"Ground structure method","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"<研究論文>骨組の位相最適化手法を用いた制震ダンパーの最適配置","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"<研究論文>骨組の位相最適化手法を用いた制震ダンパーの最適配置"}]},"item_type_id":"2","owner":"3","path":["1721","3285"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-02-21"},"publish_date":"2011-02-21","publish_status":"0","recid":"7307","relation_version_is_last":true,"title":["<研究論文>骨組の位相最適化手法を用いた制震ダンパーの最適配置"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-21T00:18:55.634050+00:00"}