{"created":"2023-06-20T16:35:54.039206+00:00","id":5346,"links":{},"metadata":{"_buckets":{"deposit":"0c8e0652-eedf-4ae1-99c0-e31e007f00e7"},"_deposit":{"created_by":3,"id":"5346","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5346"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00005346","sets":["14:923:1379:1383"]},"author_link":["42978","42979","42980"],"item_2_alternative_title_3":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"地下水シミュレーションモデルによるパキスタン・パンジャブ地方におけるスキミング井戸有効性の検証"}]},"item_2_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-03-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"32","bibliographicPageStart":"11","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"近畿大学農学部紀要"},{"bibliographic_title":"MEMOIRS OF THE FACULTY OF AGRICULTURE OF KINKI UNIVERSITY","bibliographic_titleLang":"en"}]}]},"item_2_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the results of a modeling study on skimming well performances using the MODFLOW-MT3D groundwater model in Rechna Doab of Pakistan's Punjab. After calibration and validation of the developed model using the field data, a scenario analysis was conducted to identify the best management practice for well operation. The result of the analysis showed that a 4-strainer well with 0.2 to 0.5 cfs (340 to 850 l/min) discharge and well penetration (Pw) of 30 to 40% of the 30 m thick fresh water layer is best recommended to be operated 4 to 8 hours/day to obtain water with a salinity that is less than 1500 ppm without a significant saltwater upconing on long-term basis in Rechna Doab of Pakistan's Punjab. \n<要約>本研究では, パキスタンパンジャブ州レチナドアブ地域を対象として, スキミング井戸の有効性をMODFLOW-MT3D地下水モデルを用いたシュミレーションにより検証した。 現地データを用いてモデルのキャリブレーションと再現性の検証を行った後, シナリオ分析を行い最適な井戸管理方法の摘出を試みた。 結果として, 対象地域で地下水を使用するには4-ストレイナー井戸を淡水層30メートルに対する井戸侵入率(Pw) を30-40%の深さで設置し, 揚水量を毎分340-850リットルで一日4 - 8 時間稼働させることを提案した。 この条件下においては, 地下塩水の上昇を抑えるとともに揚水の塩分濃度を1,500 ppm以下に制御できることが明らかとなった。","subitem_description_type":"Abstract"}]},"item_2_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学農学部"}]},"item_2_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"4538889","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"ASLAM, Muhammad"},{"subitem_text_language":"en","subitem_text_value":"MATSUNO, Yutaka"},{"subitem_text_language":"en","subitem_text_value":"HATCHO, Nobumasa"}]},"item_2_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"国際水管理研究所"},{"subitem_text_value":"近畿大学農学部環境管理学科"},{"subitem_text_value":"近畿大学農学部環境管理学科"}]},"item_2_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"International Water Management Institute (IWMI)"},{"subitem_text_value":"Department of Environmental Management, Faculty of Agriculture, Kinki University"},{"subitem_text_value":"Department of Environmental Management, Faculty of Agriculture, Kinki University"}]},"item_2_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"アスラム, ムハメド"},{"creatorName":"アスラム, ムハメド","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松野, 裕"},{"creatorName":"マツノ, ユタカ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"八丁, 信正"},{"creatorName":"ハッチョウ, ノブマサ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-18"}],"displaytype":"detail","filename":"AN00064044-20140331-0011.pdf","filesize":[{"value":"4.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AN00064044-20140331-0011.pdf","url":"https://kindai.repo.nii.ac.jp/record/5346/files/AN00064044-20140331-0011.pdf"},"version_id":"07c8d12e-98d9-4343-84bf-acd7107c0820"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Skimming well","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Groundwater model","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Pakistan's Punjab","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Saltwater upconing","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Salinity","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"スキミング井戸","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"地下水モデル","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"パキスタンパンジャブ州","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"塩水上昇","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"塩害","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"〈Original〉Assessment of skimming well performance in Punjab, Pakistan by groundwater simulation modeling","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"〈Original〉Assessment of skimming well performance in Punjab, Pakistan by groundwater simulation modeling","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["1383"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-06-21"},"publish_date":"2014-06-21","publish_status":"0","recid":"5346","relation_version_is_last":true,"title":["〈Original〉Assessment of skimming well performance in Punjab, Pakistan by groundwater simulation modeling"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T19:55:44.705864+00:00"}