Item type |
☆紀要論文 / Departmental Bulletin Paper(1) |
公開日 |
2022-04-27 |
タイトル |
|
|
タイトル |
<Case Reports> Successful child case of Catheter intervention for patent ductus arteriosus with ADOII closure device |
|
言語 |
en |
著者 |
Masumi, Hideki
Marutani, Satoshi
Kusano, Nobuyoshi
Uesima, Kazushi
Takada, Nori
Sugimoto, Keisuke
Inamura, Noboru
Mizutani, Kazuki
|
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題 |
Patent ductus arteriosus, Amplatzer™, Duct Occluder II, Transcatheter closer |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
departmental bulletin paper |
ID登録 |
|
|
ID登録 |
10.15100/00022603 |
|
ID登録タイプ |
JaLC |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Pediatrics, Kindai University Faculty of Medicine |
著者 所属 |
|
|
|
Department of Cardiology, Kindai University Faculty of Medicine |
版 |
|
|
出版タイプ |
NA |
|
出版タイプResource |
http://purl.org/coar/version/c_be7fb7dd8ff6fe43 |
出版者 名前 |
|
|
出版者 |
The Kindai University Medical Association |
書誌情報 |
en : ACTA MEDICA KINDAI UNIVERSITY
巻 47,
号 1,
p. 5-10,
発行日 2022-06
|
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
03866092 |
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
[Abstract] The Amplatzer™ Duct Occluder (ADO) II closure device has become available for catheterization of patent ductus arteriosus (PDA) in recent years. It has enabled the quick and safe placement of thicker PDAs. We report the case of a 20-month-old girl treated with a PDA catheter using an ADO II closure device. The patient was a 20-month-old girl weighing 7.5 kg (-2.7SD) referred to our hospital for poor weight gain. She was diagnosed with PDA. Catheter examination at our hospital revealed a Qp/Qs 2.7, 4-mm diameter Krichenko type C ductus arteriosus. An ADO II with a waist and length of 6 mm and 4 mm, respectively, was selected and placed. The time required for catheterization was 43 minutes, and the irradiation time was 7.2 minutes. There was no residual short circuit, and the treatment was completed without any serious complications. ADO II has enabled treating Krichenko type C ductus arteriosus, which was not possible with conventional coil embolism. In this report, we present the characteristics of PDA in children and the selection of ADO II with a review of the literature. |
フォーマット |
|
|
内容記述タイプ |
Other |
|
内容記述 |
application/pdf |