{"created":"2023-06-20T16:48:58.884730+00:00","id":21033,"links":{},"metadata":{"_buckets":{"deposit":"c4833a73-24c1-4766-9f7c-e1801276cd5d"},"_deposit":{"created_by":3,"id":"21033","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"21033"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00021033","sets":["14:923:2405:4599"]},"author_link":["35883","35882"],"item_2_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-03-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"13","bibliographicPageEnd":"59","bibliographicPageStart":"49","bibliographic_titles":[{"bibliographic_title":"近畿大学工業高等専門学校研究紀要"},{"bibliographic_title":"Research reports Kindai University Technical College","bibliographic_titleLang":"en"}]}]},"item_2_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have studied HEMS (Home Energy Management System). In that study, we have regarded the wireless power transmission as the most useful energy source for sensor network node. Sensor network nodes need more than 100uW average power on working. Our scope of transmitting distance from power supplier to receiver is more than 1m. In our previous study we have shown the experimental result of more than 0.55m transmitting distance with one turn small loop coil and shown the possibility of further transmission by using other kinds of coil shape under the magnetic coupled method. In the latest paper we have shown the results of using silver nano-particle paste as the magnetic flux concentrator. In this study we have clarified the advantage of applying for repeating coils between transmitting coil and receiving coil. At first we have shown the results of introducing repeating coils by measurement. Next we have defined the scope concept as the novel concept. That is the concept for guaranteeing the transmitting efficiency in the scope range. We have measured and calculated the transmitting efficiency under the assumption that scope range is defined as 1m. As the results we can show the possibility of 1m rage transmission referring to the HEMS specification.","subitem_description_type":"Abstract"}]},"item_2_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学工業高等専門学校"}]},"item_2_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18824374","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"YOSHIKAWA, Takashi"},{"subitem_text_language":"en","subitem_text_value":"KAMURO, Yuuki"}]},"item_2_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大学工業高等専門学校 総合システム工学科 電気電子コース"},{"subitem_text_value":"近畿大学工業高等専門学校 専攻科 生産システム工学専攻 電気電子工学系"}]},"item_2_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Kindai University Technical College"},{"subitem_text_value":"Kindai University Technical College"}]},"item_2_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_be7fb7dd8ff6fe43","subitem_version_type":"NA"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉川, 隆"},{"creatorName":"ヨシカワ, タカシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"禿, 優希"},{"creatorName":"カムロ, ユウキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-07-13"}],"displaytype":"detail","filename":"AA12315376-20200315-0049.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AA12315376-20200315-0049.pdf","url":"https://kindai.repo.nii.ac.jp/record/21033/files/AA12315376-20200315-0049.pdf"},"version_id":"7eca0c3f-034a-41a7-aea7-59fc181376a5"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Wireless Power Transmission","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Dense Array","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Repeating","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic Resonance","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Last 1m WPT における Denseアレイ Hopping効果の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Last 1m WPT における Denseアレイ Hopping効果の検証"},{"subitem_title":"Examination of Dense Array Hopping Effect on Last 1m WPT","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["4599"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-07-13"},"publish_date":"2020-07-13","publish_status":"0","recid":"21033","relation_version_is_last":true,"title":["Last 1m WPT における Denseアレイ Hopping効果の検証"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T18:36:27.118386+00:00"}