WEKO3
アイテム
ハードコンタクトレンズ装用時にみられる乱視の起源についての臨床および物理学的研究
https://kindai.repo.nii.ac.jp/records/2002614
https://kindai.repo.nii.ac.jp/records/200261407c367ea-af54-4dc9-b4f4-a82c6ed3d36c
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | ☆紀要論文 / Departmental Bulletin Paper(1) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2025-03-19 | |||||||||
| タイトル | ||||||||||
| タイトル | ハードコンタクトレンズ装用時にみられる乱視の起源についての臨床および物理学的研究 | |||||||||
| 言語 | ja | |||||||||
| タイトル | ||||||||||
| タイトル | Clinical and physical approaches to the source of astigmatism seen in hard contact lens wearers | |||||||||
| 言語 | en | |||||||||
| 著者 |
安本, 京子
× 安本, 京子
|
|||||||||
| 言語 | ||||||||||
| 言語 | jpn | |||||||||
| キーワード | ||||||||||
| 主題 | astigatism, hard contact lens, phakia, aphakia, pseudophakia, simulation, model eye | |||||||||
| 資源タイプ | ||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
| 資源タイプ | departmental bulletin paper | |||||||||
| 出版タイプ | ||||||||||
| 出版タイプ | AM | |||||||||
| 出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||||||
| 出版者 名前 | ||||||||||
| 出版者 | 近畿大学医学会 | |||||||||
| 言語 | ja | |||||||||
| bibliographic_information |
ja : 近畿大学医学雑誌 en : Medical Journal of Kinki University 巻 16, 号 1, p. 127-138, 発行日 1991-03-25 |
|||||||||
| ISSN | ||||||||||
| 収録物識別子タイプ | PISSN | |||||||||
| 収録物識別子 | 03858367 | |||||||||
| 内容記述 | ||||||||||
| 内容記述タイプ | Abstract | |||||||||
| 内容記述 | To investigate the source of astigmatism seen in hard contact lens wearers, changes in dioptors of astigmatism were measured using an autorefractometer in 158 eyes (84 phakic, 34 aphakic, 40 pseudophakic) wearing hard contact lenses. Regardless of whether the eye was phakic, aphakic, or pseudophakic, astigmatism as high as 0.75 dioptors was most frequently observed in hard contact lens wearers. These results suggest that the astigmatism seen in hard contact lens wearers may be induced by wearing of hard contact lenses. To test a hypothesis that vertical movement for alignment of hard contact lenses on the cornea might induce astigmatism, an attempt was made to compare values of the measured astigmatism caused by wearing a hard contact lens with those calculated by a simulation model of the eye based on the physical apposition of a hard contact lens and the cornea. The power and axis of the calculated astigmatism were very close to those of actually determined astigmatisms. This suggests that astigmatism seen in hard contact lens wearers is generated by the movement of hard contact lenses following the contact lens being out of alignment. | |||||||||
| 言語 | en | |||||||||
| 内容記述 | ||||||||||
| 内容記述タイプ | Other | |||||||||
| 内容記述 | 本文データはCiNiiから複製したものである。 | |||||||||
| 言語 | ja | |||||||||