タイトル | 4端子bipolar電気凝固法による上部消化管出血の内視鏡的止血法 | |||||||||
言語 | ja | |||||||||
タイトル | ||||||||||
タイトル | Endoscopic paired bipolar electrocoagulation for upper gastrointestinal bleeding | |||||||||
言語 | en | |||||||||
著者 |
汐見,幹夫
× 汐見,幹夫
|
|||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
キーワード | ||||||||||
主題 | upper gastrointestinal bleeding, endoscopic hemostasis, bipolar/multipolar electrocoagulation | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | departmental bulletin paper | |||||||||
出版タイプ | ||||||||||
出版タイプ | AM | |||||||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||||||
出版者 名前 | ||||||||||
出版者 | 近畿大学医学会 | |||||||||
言語 | ja | |||||||||
bibliographic_information |
ja : 近畿大学医学雑誌 en : Medical Journal of Kinki University 巻 18, 号 3, p. 403-415, 発行日 1993-09-25 |
|||||||||
ISSN | ||||||||||
収録物識別子タイプ | PISSN | |||||||||
収録物識別子 | 03858367 | |||||||||
内容記述 | ||||||||||
内容記述タイプ | Abstract | |||||||||
内容記述 | The endoscopic hemostasis method using paired bipolar electrocoagulator (BPEC) that we developed for control of upper gastrointestinal bleeding is reported and the results discussed. A total of 264 patients were treated with BPEC on 316 occasions between September 1980 and August 1992. Subjects consisted of 57 females and 207 males. Arrest of bleeding was achieved by BPEC in 307 of 316 occasions (97.2%). No complications related to the procedure were noted during the observation period. The effects of four types of electrodes, 3 bipolar electrocoagulators and 1 heater probe, were compared by in vitro experiment. The degenerative width and depth was compared on fresh human stomachs that had been resected due to perforated duodenal ulcer. It was confirmed that the mean width of the coagulated area produced by BPEC was significantly (P<0.001) smaller than that of the other three probes, and BPEC produced the deepest, yet safe degenerative depth among the four methods. We conclude that BPEC is highly effective in hemostasis and superior to various other hemostatic methods in its operability, safety, portability and equal to other methods in cost. | |||||||||
言語 | en | |||||||||
内容記述 | ||||||||||
内容記述タイプ | Other | |||||||||
内容記述 | 本文データはCiNiiから複製したものである。 | |||||||||
言語 | ja |