4端子bipolar電気凝固法による上部消化管出血の内視鏡的止血法

https://kindai.repo.nii.ac.jp/records/2002081
https://kindai.repo.nii.ac.jp/records/2002081
c6dcc9e5-76a1-49a0-8f7a-8088cab459eb
名前 / ファイル ライセンス アクション
AN00063584-19930925-0403.pdf AN00063584-19930925-0403.pdf (1.4 MB)
Item type ☆紀要論文 / Departmental Bulletin Paper(1)
公開日 2024-12-05
タイトル
タイトル 4端子bipolar電気凝固法による上部消化管出血の内視鏡的止血法
言語 ja
タイトル
タイトル Endoscopic paired bipolar electrocoagulation for upper gastrointestinal bleeding
言語 en
著者 汐見,幹夫

× 汐見,幹夫

ja 汐見,幹夫
近畿大学

en Shiomi, Mikio
Kinki University

Search repository
言語
言語 jpn
キーワード
主題 upper gastrointestinal bleeding, endoscopic hemostasis, bipolar/multipolar electrocoagulation
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
出版者 名前
出版者 近畿大学医学会
言語 ja
bibliographic_information ja : 近畿大学医学雑誌
en : Medical Journal of Kinki University

巻 18, 号 3, p. 403-415, 発行日 1993-09-25
ISSN
収録物識別子タイプ PISSN
収録物識別子 03858367
内容記述
内容記述タイプ Abstract
内容記述 The endoscopic hemostasis method using paired bipolar electrocoagulator (BPEC) that we developed for control of upper gastrointestinal bleeding is reported and the results discussed. A total of 264 patients were treated with BPEC on 316 occasions between September 1980 and August 1992. Subjects consisted of 57 females and 207 males. Arrest of bleeding was achieved by BPEC in 307 of 316 occasions (97.2%). No complications related to the procedure were noted during the observation period. The effects of four types of electrodes, 3 bipolar electrocoagulators and 1 heater probe, were compared by in vitro experiment. The degenerative width and depth was compared on fresh human stomachs that had been resected due to perforated duodenal ulcer. It was confirmed that the mean width of the coagulated area produced by BPEC was significantly (P<0.001) smaller than that of the other three probes, and BPEC produced the deepest, yet safe degenerative depth among the four methods. We conclude that BPEC is highly effective in hemostasis and superior to various other hemostatic methods in its operability, safety, portability and equal to other methods in cost.
言語 en
内容記述
内容記述タイプ Other
内容記述 本文データはCiNiiから複製したものである。
言語 ja
戻る
0
views
See details
Views

Versions

Ver.1 2024-12-05 07:19:35.328159
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3