{"created":"2023-06-20T16:48:09.372654+00:00","id":19983,"links":{},"metadata":{"_buckets":{"deposit":"a76ce0c3-5a0a-474c-9409-3b8b7d8478da"},"_deposit":{"created_by":3,"id":"19983","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"19983"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00019983","sets":["14:923:1711:4488"]},"author_link":["34035","34034","34036"],"item_2_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-12-21","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"52","bibliographicPageEnd":"37","bibliographicPageStart":"33","bibliographic_titles":[{"bibliographic_title":"近畿大学工学部研究報告"},{"bibliographic_title":"Research reports of the Faculty of Engineering, Kindai University","bibliographic_titleLang":"en"}]}]},"item_2_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[Abstract]Kyomachiya is a symbol of the history and culture of Kyoto City,and supporting the lives of people living in Kyoto. However,due to the Kumamoto earthquake,about 30% of the town house in Kumamoto was destroyed and disassembled. One of damping device type is a joint damper. However,it is difficult to judge to which joint of the frame the damper should be placed. In this paper,we propose a method to obtain the optimal placement of the damper using ESO method and Ground structure method then we will examine its effectiveness. Earthquake response analysis is performed on the model of Kyomachiya. The seismic waves used for analysis are the Kumamoto earthquake and El Centro. As a result, it was confirmed that this proposed method is an effective means for seeking excellent placement of joint damper of Kyomachi frame","subitem_description_type":"Abstract"}]},"item_2_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学工学部"}]},"item_2_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2434592X","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":" NAGAOKA,Ikuma"},{"subitem_text_language":"en","subitem_text_value":"MATSUMOTO,Shinya"},{"subitem_text_language":"en","subitem_text_value":"FUJII,Daiji"}]},"item_2_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大 学大学院システム工学研究科"},{"subitem_text_value":"近畿大学工学部建築学科"},{"subitem_text_value":"近畿大学工学部建築学科"}]},"item_2_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Graduate School of System Engineering, Kindai University"},{"subitem_text_value":"Department of Architecture, Faculty of Engineering Kindai University"},{"subitem_text_value":"Department of Architecture, Faculty of Engineering Kindai University"}]},"item_2_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_be7fb7dd8ff6fe43","subitem_version_type":"NA"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"永岡, 伊玖磨"},{"creatorName":"ナガオカ, イクマ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松本, 慎也"},{"creatorName":"マツモト, シンヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤井, 大地"},{"creatorName":"フジイ, ダイジ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-03-06"}],"displaytype":"detail","filename":"AN00063799-20181221-0033.pdf","filesize":[{"value":"610.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AN00063799-20181221-0033.pdf","url":"https://kindai.repo.nii.ac.jp/record/19983/files/AN00063799-20181221-0033.pdf"},"version_id":"52433a37-9edc-43f9-8d9e-a585749cdce3"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Optimal placement","subitem_subject_scheme":"Other"},{"subitem_subject":"ESO method","subitem_subject_scheme":"Other"},{"subitem_subject":"Ground structure method","subitem_subject_scheme":"Other"},{"subitem_subject":"Vibration damping device","subitem_subject_scheme":"Other"},{"subitem_subject":"Kyo-machi-ya","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"〈研究論文〉ESO法を用いた木造骨組における接合部装着型ダンパーの最適配置問題","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"〈研究論文〉ESO法を用いた木造骨組における接合部装着型ダンパーの最適配置問題"},{"subitem_title":"〈Original Papers〉Optimal placement problem of joint damper in wood frame using ESO method","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["4488"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-06"},"publish_date":"2019-03-06","publish_status":"0","recid":"19983","relation_version_is_last":true,"title":["〈研究論文〉ESO法を用いた木造骨組における接合部装着型ダンパーの最適配置問題"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T21:31:57.935142+00:00"}