WEKO3
アイテム
振動床発電の研究
https://kindai.repo.nii.ac.jp/records/19336
https://kindai.repo.nii.ac.jp/records/193368c155084-6af5-4c4f-97b0-99f89384536c
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | ☆紀要論文 / Departmental Bulletin Paper(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2018-05-29 | |||||||||
タイトル | ||||||||||
タイトル | 振動床発電の研究 | |||||||||
タイトル | ||||||||||
タイトル | The Study for Vibration Power Generation Floor | |||||||||
言語 | en | |||||||||
著者 |
吉川, 隆
× 吉川, 隆
|
|||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
キーワード | ||||||||||
主題 | Power, Generation, Floor, Vibration, Energy Harvesting, HEMS | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | departmental bulletin paper | |||||||||
著者(英) | ||||||||||
言語 | en | |||||||||
値 | Yoshikawa, Takashi | |||||||||
著者 所属 | ||||||||||
値 | 近畿大学工業高等専門学校総合システム工学科 電気電子コース | |||||||||
著者所属(翻訳) | ||||||||||
値 | Kindai University Technical College | |||||||||
版 | ||||||||||
出版タイプ | NA | |||||||||
出版タイプResource | http://purl.org/coar/version/c_be7fb7dd8ff6fe43 | |||||||||
出版者 名前 | ||||||||||
出版者 | 近畿大学工業高等専門学校 | |||||||||
書誌情報 |
近畿大学工業高等専門学校研究紀要 en : Research reports Kindai University Technical College 号 11, p. 39-48, 発行日 2018-03-15 |
|||||||||
ISSN | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 18824374 | |||||||||
抄録 | ||||||||||
内容記述タイプ | Abstract | |||||||||
内容記述 | Sensor Network Node (The small wireless information terminal) for HEMS (Home Energy Management System) averagely consumes lower power less than 100[μ W]. Then we have tried to consider to use the energy harvesting applying to the power supplier of the sensor network node. Many kinds of energy harvesting method has been evaluated. For example illumination energy of the room light,the difference of the temperature between human body and room and vibration energy caused by human step on the floor,magnetic flux leakage from the fluorescent lamp,micro hydraulic power generation from the water pipe,weak wind power generation through the ventilation fan was experimented. As the result we have concluded the energy harvesting is enough to use for the power supplier of the senor network end node. In this paper,we have tried to introduce routing node which is worked by the harvesting energy. That routing node is used for data hopping node between the cluster networks. At first we have defined the fundamental data transmitting protocol and calculated the energy consumption for routing node and shown the ability of the routing node with energy harvesting. Moreover, we have devised the RDA (Rotated Data Acquisition) protocol that is reducing power consumption and calculated the energy consumption. As the result we can estimated to reduce the 40% energy consumption referring to fundamental one. | |||||||||
フォーマット | ||||||||||
内容記述タイプ | Other | |||||||||
内容記述 | application/pdf |