{"created":"2023-06-20T16:47:08.916980+00:00","id":18779,"links":{},"metadata":{"_buckets":{"deposit":"cc803766-a7c5-4cc2-b93f-6fbb53d15ea3"},"_deposit":{"created_by":3,"id":"18779","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"18779"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00018779","sets":["14:2667:4374"]},"author_link":["31732"],"item_8_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"4","bibliographicPageStart":"1","bibliographic_titles":[{"bibliographic_title":"科学研究費助成事業研究成果報告書 (2016)"}]}]},"item_8_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"研究成果の概要(和文):組織等価ファントム熱ルミネセンス線量計(TEP-TLD)に粒子線治療ビームを照射したときに核反応によって生成するフラグメント粒子を測定することを目的として研究を行った。シミュレーション計算によりTEP-TLDやタフウォータファントムを標的とした場合の線量分布及びフルエンス分布を調査した後、放射線医学総合研究所の重粒子線加速器施設HIMACにおいて検出器システムのテスト実験を行った。その結果、検出器システムは治療場で発生する二次中性子による放射化に大きく影響されることが分かった。\n研究成果の概要(英文):This study was carried out to measure the fragments produced in a tissue equivalent phantom thermoluminescent dosimeter (TEP-TLD) irradiated by a particle therapeutic beam. Several experiments were performed to check detector performance by using the heavy ion medical accelerator HIMAC at NIRS after the dose and fluence distribution of each fragment produced in TEP-TLDs and tough water phantoms as targets was simulated. As result, it was found that the performance of the detector system was largely influenced by activation by secondary neutrons in treatment field.","subitem_description_type":"Abstract"}]},"item_8_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"研究種目:基盤研究(C); 研究期間:2013~2016; 課題番号:25390129; 研究分野:放射線工学; 科研費の分科・細目:","subitem_description_type":"Other"}]},"item_8_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Research Paper","subitem_description_type":"Other"}]},"item_8_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_8_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学"}]},"item_8_relation_11":{"attribute_name":"著者 外部リンク","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-25390129/"}]}]},"item_8_text_10":{"attribute_name":"著者 役割","attribute_value_mlt":[{"subitem_text_value":"研究代表者"}]},"item_8_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"WAKABAYASHI, Genichiro"}]},"item_8_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大学原子力研究所; 准教授"}]},"item_8_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Kindai University"}]},"item_8_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_be7fb7dd8ff6fe43","subitem_version_type":"NA"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"若林, 源一郎"},{"creatorName":"ワカバヤシ, ゲンイチロウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"31732","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"90311852","nameIdentifierScheme":"研究者番号","nameIdentifierURI":" "}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-11-01"}],"displaytype":"detail","filename":"25390129seika.pdf","filesize":[{"value":"203.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"25390129seika.pdf","url":"https://kindai.repo.nii.ac.jp/record/18779/files/25390129seika.pdf"},"version_id":"979adf47-5f63-4556-9132-bf2ab5080e0b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"組織等価ファントム熱ルミネセンス線量計","subitem_subject_scheme":"Other"},{"subitem_subject":"重粒子線","subitem_subject_scheme":"Other"},{"subitem_subject":"フラグメント粒子","subitem_subject_scheme":"Other"},{"subitem_subject":"線量分布測定","subitem_subject_scheme":"Other"},{"subitem_subject":"二次中性子","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"熱蛍光線量計を用いた粒子線がん治療線量分布測定におけるフラグメント粒子の影響評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"熱蛍光線量計を用いた粒子線がん治療線量分布測定におけるフラグメント粒子の影響評価"},{"subitem_title":"Influence evaluation of fragments in dose distribution measurements for particle therapy by using thermoluminescent dosimeters","subitem_title_language":"en"}]},"item_type_id":"8","owner":"3","path":["4374"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-11-01"},"publish_date":"2017-11-01","publish_status":"0","recid":"18779","relation_version_is_last":true,"title":["熱蛍光線量計を用いた粒子線がん治療線量分布測定におけるフラグメント粒子の影響評価"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T21:50:08.605501+00:00"}