{"created":"2023-06-20T16:46:38.393702+00:00","id":18150,"links":{},"metadata":{"_buckets":{"deposit":"414b8aca-78d3-4089-81a3-e558dc7364f3"},"_deposit":{"created_by":29,"id":"18150","owners":[29],"pid":{"revision_id":0,"type":"depid","value":"18150"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00018150","sets":["14:2667:4296"]},"author_link":["3197"],"item_8_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"6","bibliographicPageStart":"1","bibliographic_titles":[{"bibliographic_title":"科学研究費助成事業研究成果報告書 (2015)"}]}]},"item_8_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"研究成果の概要(和文): 現在の空調負荷計算法は、負荷計算の段階では居住者の温冷感を十分に考慮していない問題がある。この問題に対し、筆者は、空調負荷を再定義し、現在の負荷計算法を包含できる新しい負荷計算法として「居住者の温冷感を考慮した空調負荷計算法」を提案した。これまでは、この新しい計算法について一連のケーススタディーを行い、その有効性を明らかにした。本研究では、エアコンと壁放射パネルについて、温度センサーの設置位置や温度設定値の違いによる投入熱量を測定し、投入熱量と新しい負荷計算法で予測した結果との整合性を分析して「温冷感法」の有効性を確認した。\n研究成果の概要(英文): There is a problem that resident's thermal sensation isn't being considered sufficiently in the stage of load calculation with the current air-conditioning load calculation method. To settle this problem, I changed the definition of air-conditioning load, and showed an \"air-conditioning load calculation method considering resident's thermal sensation\" as new calculation method. Up to now, the validity of this new calculation method was done clearly by several numerical simulations. This research measured input energy of heating panel in different experimental conditions and confirmed the validity of the new load calculation method using measured Input Energy.","subitem_description_type":"Abstract"}]},"item_8_description_36":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"研究種目:基盤研究(C); 研究期間:2013~2015; 課題番号:25420618; 研究分野:建築環境工学; 科研費の分科・細目:","subitem_description_type":"Other"}]},"item_8_description_37":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Research Paper","subitem_description_type":"Other"}]},"item_8_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_8_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学"}]},"item_8_relation_11":{"attribute_name":"著者 外部リンク","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-25420618/"}]}]},"item_8_text_10":{"attribute_name":"著者 役割","attribute_value_mlt":[{"subitem_text_value":"研究代表者"}]},"item_8_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"CUI, Jun"}]},"item_8_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大学工学部; 教授"}]},"item_8_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Kindai University"}]},"item_8_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_be7fb7dd8ff6fe43","subitem_version_type":"NA"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"崔, 軍"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-10-15"}],"displaytype":"detail","filename":"25420618seika.pdf","filesize":[{"value":"533.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"25420618seika.pdf","url":"https://kindai.repo.nii.ac.jp/record/18150/files/25420618seika.pdf"},"version_id":"9c1f15c5-d3d2-414b-97ea-9f921e065605"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"空調負荷計算","subitem_subject_scheme":"Other"},{"subitem_subject":"温冷感","subitem_subject_scheme":"Other"},{"subitem_subject":"PMV","subitem_subject_scheme":"Other"},{"subitem_subject":"実験検証","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"居住者の温冷感を考慮した空調負荷計算法の実験検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"居住者の温冷感を考慮した空調負荷計算法の実験検証"},{"subitem_title":"Experimental Verification on Air-conditioning Load Calculation Method Considering Thermal Sensation of Resident","subitem_title_language":"en"}]},"item_type_id":"8","owner":"29","path":["4296"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-10-15"},"publish_date":"2016-10-15","publish_status":"0","recid":"18150","relation_version_is_last":true,"title":["居住者の温冷感を考慮した空調負荷計算法の実験検証"],"weko_creator_id":"29","weko_shared_id":-1},"updated":"2023-06-20T22:06:50.050859+00:00"}