@article{oai:kindai.repo.nii.ac.jp:00017721, author = {田上, 将治 and 五百井, 清}, journal = {近畿大学次世代基盤技術研究所報告, Kindai University Research Institute of Fundamental Technology for Next Generation}, month = {Jul}, note = {Various type impact and vibration isolation devices have been widely used to protect the objects particularly in the field of medical, biology, or any precision industries. These devices are mainly composed of the spring, damper and actuator. This paper proposes another new simpler method to insulate the impact disturbance by using the principle of center of percussion. When the plane rigid body is forced impulsively, the instant stationary point must be on the plane rigid body. This instant stationary point is called "center of percussion". This paper shows the basic equations, simulation and the several experimental results to realize the impact insulator using center of percussion., Ⅲ.論文集, application/pdf}, pages = {77--80}, title = {〈原著論文〉撃心原理を応用した衝撃低減方法の基礎検討}, volume = {7}, year = {2016}, yomi = {タガミ, マサハル and イオイ, キヨシ} }