{"created":"2023-06-20T16:43:01.524149+00:00","id":13798,"links":{},"metadata":{"_buckets":{"deposit":"6ec2a2c7-4410-41fd-88ef-1362cb7cf25c"},"_deposit":{"created_by":3,"id":"13798","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"13798"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00013798","sets":["14:923:2261:2271","21:3039:3842:3844"]},"author_link":["25232","25234","25235","25233"],"item_2_alternative_title_3":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"CFD Analysis on the Thermal Environment of the Full Size Experiment House Using a Detailed Building Model Part1,0n Thermal Environment of the Radiant Heating"}]},"item_2_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-06-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"111","bibliographicPageStart":"107","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"近畿大学次世代基盤技術研究所報告"},{"bibliographic_title":"Kinki University Research Institute of Fundamental Technology for Next Generation","bibliographic_titleLang":"en"}]}]},"item_2_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[Abstract] In this paper, CFD analysis of floor radiant heating and the wall radiant heating was carried out using a detailed experiment house model. The results are shown below. 1) When the outdoor air temperature is 1 degree Celsius, the comfort of the residence area cannot be kept only with a wall heating panel of 40 degrees Celsius. 2) In the residence area, a floor heating of 28 degrees Celsius may become more comfortable than wall heating of 40 degrees Celsius. 3) If a wall panel is used together with a floor panel effectively even if water supply temperature is a little lower than wall heating, indoor heat environment is improved.","subitem_description_type":"Abstract"}]},"item_2_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学次世代基盤技術研究所"}]},"item_2_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"21858802","subitem_source_identifier_type":"ISSN"}]},"item_2_text_10":{"attribute_name":"著者 役割","attribute_value_mlt":[{"subitem_text_value":"研究代表者"},{"subitem_text_value":"共同研究者"},{"subitem_text_value":"共同研究者"},{"subitem_text_value":"共同研究者"}]},"item_2_text_7":{"attribute_name":"著者(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Cui, Jun"},{"subitem_text_language":"en","subitem_text_value":"Ichikawa, Takanori"},{"subitem_text_language":"en","subitem_text_value":"Kato, Satoshi"},{"subitem_text_language":"en","subitem_text_value":"Ryu, Shoichiro"}]},"item_2_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大学工学部建築学科; 准教授"},{"subitem_text_value":"近畿大学工学部建築学科; 講師"},{"subitem_text_value":"近畿大学大学院システム工学専攻"},{"subitem_text_value":"高砂熱学工業株式会社"}]},"item_2_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Kinki University"},{"subitem_text_value":"Kinki University"},{"subitem_text_value":"Kinki University"}]},"item_2_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"崔, 軍"},{"creatorName":"&EMPTY&","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"市川, 尚紀"},{"creatorName":"イチカワ, タカノリ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加藤, 聡"},{"creatorName":"カトウ, サトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"龍, 昌一良"},{"creatorName":"リュウ, ショウイチロウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-19"}],"displaytype":"detail","filename":"AA12517632-20110600-0107.pdf","filesize":[{"value":"2.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AA12517632-20110600-0107.pdf","url":"https://kindai.repo.nii.ac.jp/record/13798/files/AA12517632-20110600-0107.pdf"},"version_id":"6b16e59e-acd7-40f3-bfa4-8df534330c52"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"〈原著論文〉詳細な建物モデルを用いた実大実験住宅の熱環境に関するCFD解析その1--放射暖房について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"〈原著論文〉詳細な建物モデルを用いた実大実験住宅の熱環境に関するCFD解析その1--放射暖房について"}]},"item_type_id":"2","owner":"3","path":["2271","3844"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-01-19"},"publish_date":"2013-01-19","publish_status":"0","recid":"13798","relation_version_is_last":true,"title":["〈原著論文〉詳細な建物モデルを用いた実大実験住宅の熱環境に関するCFD解析その1--放射暖房について"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T23:10:04.250929+00:00"}