@article{oai:kindai.repo.nii.ac.jp:00013798, author = {崔, 軍 and 市川, 尚紀 and 加藤, 聡 and 龍, 昌一良}, journal = {近畿大学次世代基盤技術研究所報告, Kinki University Research Institute of Fundamental Technology for Next Generation}, month = {Jun}, note = {[Abstract] In this paper, CFD analysis of floor radiant heating and the wall radiant heating was carried out using a detailed experiment house model. The results are shown below. 1) When the outdoor air temperature is 1 degree Celsius, the comfort of the residence area cannot be kept only with a wall heating panel of 40 degrees Celsius. 2) In the residence area, a floor heating of 28 degrees Celsius may become more comfortable than wall heating of 40 degrees Celsius. 3) If a wall panel is used together with a floor panel effectively even if water supply temperature is a little lower than wall heating, indoor heat environment is improved., application/pdf}, pages = {107--111}, title = {〈原著論文〉詳細な建物モデルを用いた実大実験住宅の熱環境に関するCFD解析その1--放射暖房について}, volume = {2}, year = {2011}, yomi = {イチカワ, タカノリ and カトウ, サトシ and リュウ, ショウイチロウ} }