WEKO3
アイテム
直立姿勢時における重心動揺の測定値
https://kindai.repo.nii.ac.jp/records/12859
https://kindai.repo.nii.ac.jp/records/12859a8cf1a48-0b3a-4ff8-8ef9-6134ffc53fdd
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | ☆紀要論文 / Departmental Bulletin Paper(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2014-07-21 | |||||||||
タイトル | ||||||||||
タイトル | 直立姿勢時における重心動揺の測定値 | |||||||||
タイトル | ||||||||||
タイトル | Measuring Data of Body Sway at Quiet Standing Posture | |||||||||
言語 | en | |||||||||
著者 |
山本, 広樹
× 山本, 広樹
|
|||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
キーワード | ||||||||||
主題 | Body sway, Standing posture, Force plate Stabilometer, Motion sickness | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | departmental bulletin paper | |||||||||
著者(英) | ||||||||||
言語 | en | |||||||||
値 | YAMAMOTO, Hiroki | |||||||||
著者 所属 | ||||||||||
値 | 近畿大学工業高等専門学校総合システムエ学科機械システムコース | |||||||||
著者所属(翻訳) | ||||||||||
値 | Kinki University Technical College | |||||||||
版 | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||
出版者 名前 | ||||||||||
出版者 | 近畿大学工業高等専門学校 | |||||||||
書誌情報 |
近畿大学工業高等専門学校研究紀要 en : Research reports Kinki University Technical College 巻 6, p. 23-26, 発行日 2013-03-01 |
|||||||||
ISSN | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 18824374 | |||||||||
抄録 | ||||||||||
内容記述タイプ | Abstract | |||||||||
内容記述 | [Abstract] Quiet standing posture is very unstable state. Therefore person always are swaying even while standing calmly. And such body sways are often estimated from center-of-pressure (COP) measures derived from force plate data. On one hand, aiming at the quantitative evaluation of a carsickness state, we are investigating the influence on this body sway at boarding to cars. In order to know the normal state as comparison data, we put the measurements of body sway about 212 subjects from 3 to 79 years old into practice. Measurements were carried out under the condition whichopened and closed eyes for 30 seconds. Sampling rate was 100s/s and cut-off frequency of LPF was set to 10Hz. From these experimental time series data, we estimated some evaluation indices ; Locus length (a) 34cm б≒15, (b) 44cm б≒21, Area of sway (Rectangular) (a) 3.6cm2б≒ 8.5, (b) 4.4cm2б≒ 9.0, (Mean circle) (a) 0.9cm2б≒ 1.9, (b) 0.9cm2б≒1.2, here (a) stands for under opened eyes, (b) stands for closed eyes. In addition to this, Locus length per unit area, Mean instantaneous speed and Maximum instantaneous speed were also calculated. However, those values are the mean values of overall data. The tendency of the change in index values between opened and closed eyes were different in each subject. | |||||||||
フォーマット | ||||||||||
内容記述タイプ | Other | |||||||||
内容記述 | application/pdf |