ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. Public
  2. 研究紀要
  3. Acta Medica Kindai University
  4. 34(2)2009
  1. Private
  2. 研究紀要
  3. Acta medica Kinki University
  4. 34(2)2009

Usefulness of perfusion index in evaluation of stellate ganglion block

https://kindai.repo.nii.ac.jp/records/10487
https://kindai.repo.nii.ac.jp/records/10487
49fcf13f-d9ce-4c32-bd80-f43547de3327
名前 / ファイル ライセンス アクション
AA0050842X-20091200-0083.pdf AA0050842X-20091200-0083.pdf (206.2 kB)
Item type ☆紀要論文 / Departmental Bulletin Paper(1)
公開日 2010-06-01
タイトル
タイトル Usefulness of perfusion index in evaluation of stellate ganglion block
言語 en
著者 Shiokawa, Yasuhiro

× Shiokawa, Yasuhiro

Shiokawa, Yasuhiro

ja-Kana シオカワ, ヤスヒロ

Search repository
Morimoto, Masahiro

× Morimoto, Masahiro

Morimoto, Masahiro

ja-Kana モリモト, マサヒロ

Search repository
O, Jinsei

× O, Jinsei

O, Jinsei

Search repository
Kamamoto, Hiromichi

× Kamamoto, Hiromichi

Kamamoto, Hiromichi

ja-Kana カマモト, ヒロミチ

Search repository
Uchida, Tomohisa

× Uchida, Tomohisa

Uchida, Tomohisa

ja-Kana ウチダ, トモヒサ

Search repository
Koga, Yoshihisa

× Koga, Yoshihisa

Koga, Yoshihisa

ja-Kana コガ, ヨシヒサ

Search repository
言語
言語 eng
キーワード
主題 stellate ganglion block, pulse oximeter, perfusion index
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者所属(翻訳)
値 Department of Anesthesiology, Kinki University School of Medicine
著者所属(翻訳)
値 Department of Anesthesiology, Kinki University School of Medicine
著者所属(翻訳)
値 Department of Anesthesiology, Kinki University School of Medicine
著者所属(翻訳)
値 Department of Anesthesiology, Kinki University School of Medicine
著者所属(翻訳)
値 Department of Anesthesiology, Kinki University School of Medicine
著者所属(翻訳)
値 Department of Anesthesiology, Kinki University School of Medicine
版
出版タイプ NA
出版タイプResource http://purl.org/coar/version/c_be7fb7dd8ff6fe43
出版者 名前
出版者 The Kinki University Medical Association
書誌情報 en : ACTA MEDICA KINKI UNIVERSITY

巻 34, 号 2, p. 83-86, 発行日 2009-12-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 03866092
抄録
内容記述タイプ Abstract
内容記述 Clinical conditions such as Horner's syndrome and conjunctival injection have conventionally been used post-treatment to evaluate stellate ganglion block (SGB). Recently, there have been occasional reports of using a perfusion index (PI) obtained using a pulse oximeter to evaluate improved peripheral blood flow. In this study, we investigated whether the PI value from the blocked side is useful in evaluating the effects of SGB following treatment. A pulse oximeter sensor was placed on the fingertip of a patient diagnosed with glossalgia, and after measuring the PI value to use as the control value, SGB was performed 10 times. PI values before and after the procedure were compared, and while the PI value fell significantly immediately following the procedure, it then rose significantly between 2 and 20 minutes after treatment, peaking at about the 5-minute mark. In the post-SGB evaluation, conditions such as Horner's syndrome and conjunctival injection were acknowledged on the blocked side. SGB blocks the sympathetic nerves and increases the volume of blood flow in the head and neck, face, and extremitas thoracica of the affected side, improving peripheral circulation. Accordingly, the PI value, which is said to correlate with peripheral blood flow, can be considered useful in evaluating the effects of SGB. In this case, the PI value in the fingertips on the blocked side rose following the SGB, peaking at approximately the 5-minute mark, clearly indicating increased peripheral blood flow from the initial phase after the SGB. The PI value was therefore considered useful in evaluating the effects of SGB.
内容記述
内容記述タイプ Other
内容記述 Oh, Jinsei
フォーマット
内容記述タイプ Other
内容記述 application/pdf
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 18:49:28.032506
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3