{"created":"2023-06-20T16:40:14.394530+00:00","id":10441,"links":{},"metadata":{"_buckets":{"deposit":"1c8d9ba8-a204-467e-b7a7-aa6bec156c49"},"_deposit":{"created_by":3,"id":"10441","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"10441"},"status":"published"},"_oai":{"id":"oai:kindai.repo.nii.ac.jp:00010441","sets":["14:923:1477:1483","21:3039:3456:3474"]},"author_link":["20080","20081","20082","20079"],"item_2_biblio_info_21":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-06-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1-2","bibliographicPageEnd":"78","bibliographicPageStart":"69","bibliographicVolumeNumber":"39","bibliographic_titles":[{"bibliographic_title":"近畿大学医学雑誌"},{"bibliographic_title":"Medical journal of Kinki University","bibliographic_titleLang":"en"}]}]},"item_2_description_33":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[抄録] 視野検査には, 静的と動的視野検査がある. 近年, 自動視野計を用いて, 両視野測定の結果を中心0°で重ね合わせることにより, 中心視野と周辺視野を同時に評価する試みがある. しかし, 動的視標は, 静的視標よりも刺激強度が強く, 静的動的視野乖離(statokinetic dissociation; SKD)という現象が存在すると報告されている. このSKDの影響により, 静的視野と動的視野の測定結果が異なる場合があるため, 単純に両視野検査の結果を重ね合わせることは出来ない. 今回我々は, 正常者5例5眼を対象に, Octopus 900を用いて, Ⅲ/4e, Ⅰ/4e, Ⅰ/3e, Ⅰ/2e, Ⅰ/1e, 視標速度1~10°/sec, の測定条件(50種)で鼻側経線(135°, 225°)上の通常の動的閾値(kinetic threshold; KT)と反応時間を考慮した動的閾値(corrected KT; cKT)を検出した. そして, 同部位で静的視野測定を行い(サイズⅢ), 各KTと静的閾値(static threshold; ST)の対応について検討した. さらに, 緑内障症例25例25眼を対象に, Goldmann視野計とHumphrey Field Analyzerの結果を比較し, Ⅰ/4e, Ⅰ/3e, Ⅰ/2e, Ⅰ/1eに対応するSTの評価を行った. 正常者において, 視標速度4°/secの場合, KTにおける生理的SKDは, Ⅲ/4eは-1.27dB, Ⅰ/4eは1.29dB, Ⅰ/3eは1.70dB, Ⅰ/2eは2.09dB, Ⅰ/1eは3.01dBであり, 視野の中心に近づくにつれて, 生理的SKDは増大する傾向にあり, 網膜偏心度依存性を認めた. しかし, cKTにおけるSKDは, Ⅲ/4eは2.63dB, Ⅰ/4eは4.32dB, Ⅰ/3eは3.72dB, Ⅰ/2eは3.19dB, Ⅰ/1eは3.63dBであり, 網膜偏心度依存性は認めなかった. 緑内障症例において, Ⅰ/4eは4.2dB, Ⅰ/3eは4.3dB, Ⅰ/2eは4.9dB, Ⅰ/1eは4.9dBのSKDを認めた. 動的視野と静的視野結果を重ね合わせる場合, 視野の中心に近づくにつれて, 生理的SKDを考慮する必要がある. cKTの場合, 全視野において, SKDを考慮する必要がある.","subitem_description_type":"Abstract"}]},"item_2_description_41":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_publisher_14":{"attribute_name":"出版者 名前","attribute_value_mlt":[{"subitem_publisher":"近畿大学医学会"}]},"item_2_source_id_22":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03858367","subitem_source_identifier_type":"ISSN"}]},"item_2_text_8":{"attribute_name":"著者 所属","attribute_value_mlt":[{"subitem_text_value":"近畿大学医学部眼科学教室"},{"subitem_text_value":"近畿大学医学部眼科学教室"},{"subitem_text_value":"近畿大学医学部眼科学教室"},{"subitem_text_value":"近畿大学医学部眼科学教室"}]},"item_2_text_9":{"attribute_name":"著者所属(翻訳)","attribute_value_mlt":[{"subitem_text_value":"Kinki University"},{"subitem_text_value":"Kinki University"},{"subitem_text_value":"Kinki University"},{"subitem_text_value":"Kinki University"}]},"item_2_version_type_12":{"attribute_name":"版","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"萱澤, 朋泰"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"奥山, 幸子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松本, 長太"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"下村, 嘉一"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-18"}],"displaytype":"detail","filename":"AN00063584-20140625-0069.pdf","filesize":[{"value":"2.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AN00063584-20140625-0069.pdf","url":"https://kindai.repo.nii.ac.jp/record/10441/files/AN00063584-20140625-0069.pdf"},"version_id":"ea6439fd-cdaf-4271-b1e5-2faf523a503f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"静的動的視野乖離","subitem_subject_scheme":"Other"},{"subitem_subject":"自動動的視野計","subitem_subject_scheme":"Other"},{"subitem_subject":"正常者","subitem_subject_scheme":"Other"},{"subitem_subject":"緑内障","subitem_subject_scheme":"Other"},{"subitem_subject":"Octopus 900","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"〈原著〉自動視野計による静的動的視野乖離の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"〈原著〉自動視野計による静的動的視野乖離の検討"}]},"item_type_id":"2","owner":"3","path":["1483","3474"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-08-05"},"publish_date":"2014-08-05","publish_status":"0","recid":"10441","relation_version_is_last":true,"title":["〈原著〉自動視野計による静的動的視野乖離の検討"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T23:40:55.132861+00:00"}