WEKO3
アイテム
{"_buckets": {"deposit": "3aad4b03-b507-4a54-8f21-bddc801a2cbb"}, "_deposit": {"created_by": 3, "id": "11472", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "11472"}, "status": "published"}, "_oai": {"id": "oai:kindai.repo.nii.ac.jp:00011472", "sets": ["1829"]}, "author_link": ["22075", "22076"], "item_2_alternative_title_3": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Study on the Photovoltaic Generation System Suitable for Sun Direction Installed Reflector: Prediction of solar irradiance on PV panel and results of power generation"}]}, "item_2_biblio_info_21": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "13", "bibliographicPageEnd": "34", "bibliographicPageStart": "27", "bibliographic_titles": [{"bibliographic_title": "かやのもり:近畿大学産業理工学部研究報告"}, {"bibliographic_title": "Reports of School of Humanity-Oriented Science and Engineering, Kinki University", "bibliographic_titleLang": "en"}]}]}, "item_2_date_19": {"attribute_name": "日付 作成日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2010-12-22", "subitem_date_issued_type": "Created"}]}, "item_2_description_33": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "When the photovoltaic generation system suitable for sun direction installed reflector was designed, the solar irradiance on PV panel by a fixed method and a tracking one was calculated. Moreover, the installation angle installed the upper and lower side reflector, the reflected solar radiation, and the shadow length were calculated. As a result, it is cleared that the tracking is effective on the clear days except at noon, the best angle installed upper reflector is from 20 to 30 degree, and the one installed lower reflector is 60 degree. The measuring data was obtained from September 2009 to February 2010 except for the period in bad condition of instruments and in unseasonable weather. As a result, an actual measurement of power conversion efficiency of PV panel was obtained from measuring data in February 2010 when the PV panel was fixed in the direction to directly south.", "subitem_description_type": "Abstract"}]}, "item_2_description_37": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Departmental Bulletin Paper", "subitem_description_type": "Other"}]}, "item_2_description_41": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_publisher_14": {"attribute_name": "出版者 名前", "attribute_value_mlt": [{"subitem_publisher": "近畿大学産業理工学部"}]}, "item_2_source_id_22": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13495801", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_15": {"attribute_name": "出版社 カナ", "attribute_value_mlt": [{"subitem_text_value": "キンキ ダイガク サンギョウ リコウ ガクブ"}]}, "item_2_text_16": {"attribute_name": "出版社 ローマ字", "attribute_value_mlt": [{"subitem_text_value": "Kinki daigaku sangyo riko gakubu"}]}, "item_2_text_17": {"attribute_name": "出版年(from)", "attribute_value_mlt": [{"subitem_text_value": "2010"}]}, "item_2_text_18": {"attribute_name": "出版年(to)", "attribute_value_mlt": [{"subitem_text_value": "12-10"}]}, "item_2_text_44": {"attribute_name": "ID(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "AA12013209-20101210-0027"}]}, "item_2_text_47": {"attribute_name": "日付 記録日(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "2010-12-22"}]}, "item_2_text_51": {"attribute_name": "最終更新日(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "Dec 22, 2010 09:00:00"}]}, "item_2_text_53": {"attribute_name": "登録者(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "kurepo"}]}, "item_2_text_54": {"attribute_name": "閲覧数(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "84"}]}, "item_2_text_55": {"attribute_name": "ダウンロード数(XooNIps)", "attribute_value_mlt": [{"subitem_text_value": "141"}]}, "item_2_text_56": {"attribute_name": "XooNIps_ITEM_KEY", "attribute_value_mlt": [{"subitem_text_value": "8725"}]}, "item_2_text_7": {"attribute_name": "著者(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Saito, Kenji"}, {"subitem_text_language": "en", "subitem_text_value": "Yoda, Hirotoshi"}]}, "item_2_text_8": {"attribute_name": "著者 所属", "attribute_value_mlt": [{"subitem_text_value": "近畿大学産業理工学部建築・デザイン学科; 教授"}, {"subitem_text_value": "近畿大学産業理工学部建築・デザイン学科; 教授"}]}, "item_2_version_type_12": {"attribute_name": "版", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_be7fb7dd8ff6fe43", "subitem_version_type": "NA"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "齋藤, 健二"}, {"creatorName": "サイトウ, ケンジ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "22075", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "依田, 浩敏"}, {"creatorName": "ヨダ, ヒロトシ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "22076", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AA12013209-20101210-0027.pdf", "filesize": [{"value": "1.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1500000.0, "url": {"label": "AA12013209-20101210-0027.pdf", "url": "https://kindai.repo.nii.ac.jp/record/11472/files/AA12013209-20101210-0027.pdf"}, "version_id": "10e222e6-9590-415c-b6be-bd3c4f026b08"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "太陽光発電", "subitem_subject_scheme": "Other"}, {"subitem_subject": "太陽光追尾", "subitem_subject_scheme": "Other"}, {"subitem_subject": "反射板", "subitem_subject_scheme": "Other"}, {"subitem_subject": "日射量予測", "subitem_subject_scheme": "Other"}, {"subitem_subject": "photovoltaic generation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "sun tracking", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reflector", "subitem_subject_scheme": "Other"}, {"subitem_subject": "solar irradiance", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "[論文]反射板方式太陽光追尾型発電装置に関する調査研究--日射量予測と発電実績について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "[論文]反射板方式太陽光追尾型発電装置に関する調査研究--日射量予測と発電実績について"}]}, "item_type_id": "2", "owner": "3", "path": ["1829", "3612"], "permalink_uri": "https://kindai.repo.nii.ac.jp/records/11472", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-12-22"}, "publish_date": "2010-12-22", "publish_status": "0", "recid": "11472", "relation": {}, "relation_version_is_last": true, "title": ["[論文]反射板方式太陽光追尾型発電装置に関する調査研究--日射量予測と発電実績について"], "weko_shared_id": -1}
[論文]反射板方式太陽光追尾型発電装置に関する調査研究--日射量予測と発電実績について
https://kindai.repo.nii.ac.jp/records/11472
https://kindai.repo.nii.ac.jp/records/114725ba7b678-eb24-4d53-882b-3d8576e9c9d8
名前 / ファイル | ライセンス | アクション |
---|---|---|
AA12013209-20101210-0027.pdf (1.5 MB)
|
|
Item type | ☆紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-12-22 | |||||
タイトル | ||||||
タイトル | [論文]反射板方式太陽光追尾型発電装置に関する調査研究--日射量予測と発電実績について | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Study on the Photovoltaic Generation System Suitable for Sun Direction Installed Reflector: Prediction of solar irradiance on PV panel and results of power generation | |||||
著者 |
齋藤, 健二
× 齋藤, 健二× 依田, 浩敏 |
|||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | 太陽光発電, 太陽光追尾, 反射板, 日射量予測, photovoltaic generation, sun tracking, reflector, solar irradiance | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者(英) | ||||||
en | ||||||
Saito, Kenji | ||||||
著者(英) | ||||||
en | ||||||
Yoda, Hirotoshi | ||||||
著者 所属 | ||||||
近畿大学産業理工学部建築・デザイン学科; 教授 | ||||||
著者 所属 | ||||||
近畿大学産業理工学部建築・デザイン学科; 教授 | ||||||
版 | ||||||
出版タイプ | NA | |||||
出版タイプResource | http://purl.org/coar/version/c_be7fb7dd8ff6fe43 | |||||
出版者 名前 | ||||||
出版者 | 近畿大学産業理工学部 | |||||
書誌情報 |
かやのもり:近畿大学産業理工学部研究報告 en : Reports of School of Humanity-Oriented Science and Engineering, Kinki University 号 13, p. 27-34, 発行日 2010-12-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13495801 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | When the photovoltaic generation system suitable for sun direction installed reflector was designed, the solar irradiance on PV panel by a fixed method and a tracking one was calculated. Moreover, the installation angle installed the upper and lower side reflector, the reflected solar radiation, and the shadow length were calculated. As a result, it is cleared that the tracking is effective on the clear days except at noon, the best angle installed upper reflector is from 20 to 30 degree, and the one installed lower reflector is 60 degree. The measuring data was obtained from September 2009 to February 2010 except for the period in bad condition of instruments and in unseasonable weather. As a result, an actual measurement of power conversion efficiency of PV panel was obtained from measuring data in February 2010 when the PV panel was fixed in the direction to directly south. | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf |